lithium-ion

22min Fast Charging

Fast Charging with Cooling fan Cooling-fan

It is necessary to cool down the battery before you begin to charge it when you charge the battery, which is the high temperature after use. MAKITA developed the original charger system; Built-in the cooling fan. The stand-by time until the charge starts is greatly shortened by cooling efficiently. In addition, the charger keeps cooling while charging it, and the rapid charge is achieved.

The charging time in practical condition

In case that the battery that became 70 degrees C right after use is charged in the environment of 25 degrees C.

Cooling-fan

Well Balanced Cooling

The design which air ows eciently overall and it can cool cell evenly and rapidly. Well-balanced cooling system prevents the load only to a part of cell and makes battery life longer.

Cooling-fan
Cooling-fan
Cooling-fan
Cooling-fan

40%Lighter

Cooling-fan

Firm Holding

Multi-contact terminals reduce electrical resistance and increase connection stability withstanding against vibration, and ultimately ensures Stable current supply to the tool.

Cooling-fan

430% Extreme Stamina Life time work volume

The charger communicates with the individual cell in battery and then it controls current, voltage, and temperature. The both rapid and optimum charge was achieved. It made battery life longer.

Total Power Delivery Amount of each battery's service lifetime

Cooling-fan
Cooling-fan

Built-in-CPU

The built-in CPU in battery records the battery usage history and transmits it to the charger.

Cooling-fan
Cooling-fan

Built-in-CPU

The CPU built in the charger analyzes its condition; high temperature, re-charge after full charged, over-discharging. The battery lasts long life because it can be charged at the best method and time.

Cooling-fan

Well Balanced Charging

MAKITA: Capacity Balanced Battery Pack

Cooling-fan
  1. It is designed that an individual cell whose condition is full, discharge, empty works well. It is hard to become the over-discharge and an overcharge because the individual cell capacity prevent to anomalies.
  2. It is possible to use it efficiency because the capacity of each cell is not uneven and discharge evenly.

Competitor A : Capacity Unbalanced Battery Pack

Cooling-fan
  1. Competitor charging system causes to decrease the capacity of the cell, which weakened by the heavy load work because Competitors do not install an optimum charge.
  2. Discharge stops by using the capacity of the weakened cell completely, when you use the power tool in the condition, noted as above. Therefore the capacities of other cells are not used completely, so that workloads are decreased at a charge.

Anytime Charge

No Memory Effect
No discharging required
Cooling-fan

Shock Absorbing

Heavy Duty Pack
Cooling-fan

Longtime Storage

Low Self Discharge
Cooling-fan